TERRACE 1 – On the onshore part of the investigation site “Terrace 1”, 46 boreholes are drilled to max. 41.00 meters of depth. Furthermore, 5 nos pressuremeter tests, 8 nos permeability tests, 1 no seismic refraction, 1 no seismic reflection, 4 nos electric resistivity tests,laboratory tests are carried out and 2 nos casagrande type standpipe are installed for ground water monitoring.
TERRACE 2 – On the onshore part of the investigation site “Terrace 2”, 102 boreholes are drilled to max. 40.50 meters of depth. Furthermore, 11 nos pressuremeter tests, 8 nos permeability tests, 1 nos water pressure tests, 8 nos seismic refraction, 4 nos seismic reflection, 11 nos seismic down-hole tests and 7 nos seismic cross-hole tests, 22 nos electric resistivity tests, laboratory tests are carried out and 4 nos Casagrande type standpipe piezometers are installed ground water monitoring.
TERRACE 3 – On the onshore part of the investigation site “Terrace 3”, 60 boreholes are drilled to max. 41.00 meters of depth. Furthermore, 7 nos pressuremeter tests, 8 nos permeability tests, 3 nos seismic refraction, 3 nos seismic reflection, 4 nos seismic down-hole tests and 1 nos seismic cross-hole tests, 8 nos electric resistivity tests, 1 no thermal resistivity test , laboratory tests are carried out and 3 nos Casagrande type standpipe piezometers are installed ground water monitoring.
TERRACE 4 – On the onshore part of the investigation site “Terrace 4”, 113 boreholes are drilled to max. 40.00 meters of depth. Furthermore, 8 nos pressuremeter tests, 12 nos permeability tests, 6 nos seismic refraction, 3 nos seismic reflection, 7 nos seismic down-hole tests and 3 nos seismic cross-hole tests, 22 nos electric resistivity tests, 1 no thermal resistivity tests, laboratory tests are carried out and 6 nos casagrande type stand-pipe piezometers are installed for ground
water monitoring.
TERRACE 5 – On the onshore part of the investigation site “Terrace 5”, 70 boreholes are drilled to max. 60.00 meters of depth. Furthermore, 5 nos pressuremeter tests, 6 nos permeability tests, 10 nos seismic refraction, 4 nos seismic reflection, 1 no seismic down-hole tests and 1 no seismic cross-hole tests, 16 nos electric resistivity tests, laboratory tests are carried out and 3 nos casagrande type standpipe piezometers are installed for ground water monitoring.
TERRACE 6 – On the onshore part of the investigation site “Terrace 6”, 38 boreholes are drilled to max. 50.00 meters of depth. Furthermore, 4 nos pressuremeter tests, 7 nos permeability tests, 7 nos seismic refraction, 4 nos seismic reflection, 2 nos seismic down-hole tests, 5 nos electric resistivity tests and laboratory tests are carried out and 1 no casagrande type standpipe are installed for ground water monitoring
OFFSHORE – On the Off shore part of the investigation, 35 boreholes are drilled to
max. 83.50 meters of depth and laboratory tests are executed on